Category:
Product description
Polyimide film is a flexible, high-temperature-resistant insulation film designed for demanding electrical and industrial applications. The supplied product range covers thin films from 12.5 μm to 100 μm and thicker films from 125 μm to 250 μm. Each grade has defined basis weight, tensile strength, breaking elongation, dielectric strength and long-term heat-resistance values.
The combination of electrical insulation, mechanical strength and long-term heat resistance makes the film suitable for applications in semiconductors, smart cards, electronics, automotive components and general manufacturing.
|
Thickness (μm) |
Basis Weight (g/m²) |
Tensile (MPa) |
Elongation (%) |
Dielectric Strength (kV/mm) |
Long-Term Heat Resistance (°C) |
|
12.5 ± 3 |
18 ± 3 |
≥140 |
≥40 |
≥210 |
≥180 |
|
15 ± 3 |
21 ± 4 |
≥140 |
≥40 |
≥210 |
≥180 |
|
25 ± 3 |
35 ± 5 |
≥140 |
≥40 |
≥245 |
≥180 |
|
30 ± 3 |
42 ± 5 |
≥140 |
≥40 |
≥230 |
≥180 |
|
50 ± 3 |
70 ± 5 |
≥140 |
≥40 |
≥220 |
≥180 |
|
75 ± 3 |
105 ± 5 |
≥150 |
≥50 |
≥180 |
≥180 |
|
100 ± 3 |
145 ± 5 |
≥150 |
≥50 |
≥175 |
≥180 |
|
Thickness (μm) |
Basis Weight (g/m²) |
Tensile (MPa) |
Elongation (%) |
Dielectric Strength (kV/mm) |
Long-Term Heat Resistance (°C) |
|
125 |
175 ± 5 |
≥150 |
≥70 |
≥170 |
≥180 |
|
150 |
215 ± 5 |
≥150 |
≥70 |
≥165 |
≥180 |
|
175 |
245 ± 5 |
≥140 |
≥80 |
≥160 |
≥180 |
|
200 |
280 ± 5 |
≥140 |
≥80 |
≥150 |
≥180 |
|
225 |
315 ± 5 |
≥130 |
≥90 |
≥145 |
≥180 |
|
250 |
350 ± 5 |
≥130 |
≥90 |
≥140 |
≥180 |
The values above are grade-specific requirements taken from the two supplied TDS documents. Select a grade by the complete property set rather than thickness alone. Product suitability should be verified in the final insulation system.
|
Property |
12.5–100 μm Grades |
125–250 μm Grades |
|
Volume resistivity |
>1 × 10¹⁰ Ω·m (TDS condition marked at 200°C) |
>1 × 10¹⁰ Ω·m |
|
Surface resistivity |
>1 × 10¹³ Ω (TDS condition marked at 200°C) |
>1 × 10¹⁴ Ω |
|
Dielectric constant at 50 Hz |
3.5 ± 0.4 |
3.5 ± 0.4 |
The supplied TDS documents present different surface-resistivity requirements for the thin and thick ranges. Confirm the applicable test condition and acceptance criterion for the selected grade before design approval.
Handle the film carefully during transportation to avoid surface or edge damage that may affect tensile performance. Store it in a ventilated warehouse, keep it away from wet floors and avoid direct sunlight. The conventional packaging stated in the TDS is carton packaging.
Send us your required thickness, width, roll format, electrical-insulation target and processing conditions. We can review the available grade and converting requirements before sampling or quotation.
My Wechat:TINO-Tina or 13694945590
WhatsApp:+86 13694945590
Email:world@dilo-china.com
Keywords:
Prev:
Next:
Message
Professional service team answers